{"product_id":"nbt1le-63-mini-rcbo-circuit-breaker-1p-n-25a-230v-6ka-30ma","title":"NBT1LE-63 Mini RCBO Circuit Breaker 1P+N 25A 230V 6kA 30mA","description":"\u003cp style=\"margin:1em 0\"\u003eEnsure reliable electrical safety with this compact NBT1LE-63 residual current circuit breaker with overload protection (RCBO). Engineered for residential and commercial low-voltage distribution systems, it delivers essential earth leakage, overload, and short-circuit protection with a 6kA breaking capacity.\u003c\/p\u003e\u003cp style=\"margin:1em 0\"\u003eFeaturing a standard DIN rail mounting design, this 1P+N breaker operates at 230V 50Hz with a rapid trip response time of 0.1 seconds or less. The durable plastic housing ensures safe, dependable performance for modern circuit management.\u003c\/p\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eKey Features\u003c\/h3\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eModel Number\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNBT1LE-63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRCBO (Residual Current Breaker with Overcurrent Protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e1P+N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eBreaking Capacity\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eRated Residual Operating Current\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eResidual Current Off-Time\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e≤0.1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eTripping Curve\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eC Curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eDIN Rail Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eHousehold, Circuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003ePackage Dimensions\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e3.9 x 3.9 x 3.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:0;padding:0.4em 0.75em 0.4em 0;opacity:0.65;vertical-align:top\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"border:0;padding:0.4em 0;vertical-align:top\"\u003e0.7 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eHighlights\u003c\/h3\u003e\n\u003cul style=\"margin:1em 0\"\u003e\n\u003cli\u003eIntegrated overload, short-circuit, and earth leakage protection\u003c\/li\u003e\n\u003cli\u003e6kA breaking capacity with Type C tripping curve\u003c\/li\u003e\n\u003cli\u003eFast residual current tripping time of 0.1 seconds or less\u003c\/li\u003e\n\u003cli\u003eConvenient standard DIN rail mounting design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eCompatibility\u003c\/h3\u003e\n\u003cp style=\"margin:1em 0\"\u003eCompatible with standard DIN rail low-voltage consumer distribution boxes and panels operating at 230V 50Hz electrical systems.\u003c\/p\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0\"\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\n\u003ch3 style=\"margin:1.25em 0 0.5em\"\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cstyle\u003e.pu-faq[open]\u003esummary .pu-faq-c{transform:rotate(180deg)}\u003c\/style\u003e\n\u003ctable class=\"pu-table\" style=\"width:100%;border-collapse:separate;border-spacing:0;border:0;box-shadow:none;outline:none;background:none;table-layout:fixed;margin:0 0 1em\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat protection does this RCBO provide?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThis RCBO provides combined protection against residual current (earth leakage), overload, and short circuits.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the breaking capacity and tripping response time?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eIt features a 6kA breaking capacity and a rapid residual current off-time of 0.1 seconds or less.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0;border-bottom:1px solid rgba(128,128,128,0.16);border-bottom:1px solid color-mix(in srgb,currentColor 12%,transparent)\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eHow is this circuit breaker mounted?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eIt is designed for standard rail mounting in distribution boards and consumer units.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd style=\"border:0;padding:0\"\u003e\u003cdetails class=\"pu-faq\" style=\"padding:0.45em 0\"\u003e\u003csummary style=\"cursor:pointer;display:flex;align-items:center;justify-content:space-between;gap:10px;list-style:none\"\u003e\u003cstrong\u003eWhat is the rated residual operating current?\u003c\/strong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 24 24\" width=\"18\" height=\"18\" fill=\"none\" stroke=\"currentColor\" stroke-width=\"1.75\" stroke-linecap=\"round\" stroke-linejoin=\"round\" class=\"pu-faq-c\" style=\"width:1em;height:1em;flex:none;opacity:0.6;transition:transform 0.15s\" aria-hidden=\"true\"\u003e\u003cpath d=\"M6 9l6 6l6 -6\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/summary\u003e\u003cp style=\"margin:0.4em 0 0\"\u003eThe rated residual operating current for earth leakage protection is 30mA.\u003c\/p\u003e\u003c\/details\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\u003c\/tbody\u003e\u003c\/table\u003e","brand":"al-mm-tech","offers":[{"title":"White \/ 1P+N \/ 25 A","offer_id":51755768381673,"sku":"107787685390","price":369.63,"currency_code":"BDT","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0791\/5166\/1289\/files\/Hafd29b6649e4455eb1be9dd94b0c8ab4r.webp?v=1787997498","url":"https:\/\/al-mm-tech.com\/products\/nbt1le-63-mini-rcbo-circuit-breaker-1p-n-25a-230v-6ka-30ma","provider":"AL-MM Tech","version":"1.0","type":"link"}